Crossover Blocks

 

2-Way

Attribute

Commands

Index

Value Range

Cut-Off Freq.

XOVR2FC

SET, SETL, GET, GETL, SETD, GETD

1

20 ~ 20000 *

 

* Can contain a decimal number.

 

 

3-Way

Attribute

Commands

Index

Value Range

Cut-Off Freq.

XOVR3FC

SET, SETL, GET, GETL, SETD, GETD

1

20 ~ 20000 *

 

* Can contain a decimal number.

 

 

4-Way

Attribute

Commands

Index

Value Range

Cut-Off Freq.

XOVR4FC

SET, SETL, GET, GETL, SETD, GETD

1

20 ~ 20000 *

 

* Can contain a decimal number.

 

Notes:

 

 2-way crossover:

 

  Index1 = 1 is the low-pass filter cut-off frequency

  Index1 = 2 is the high-pass filter cut-off frequency

 

 3-Way crossover:

 

  Index1 = 1 is low-pass filter cut-off frequency

  Index1 = 2 is the lower slope of the mid filter cut-off frequency

  Index1 = 3 is the higher slope of the mid filter cut-off frequency

  Index1 = 4 is the high-pass filter cut-off frequency

 

 4-way crossover:

 

  Index1 = 1 is the low-pass filter cut-off frequency

  Index1 = 2 is the lower slope of the low-mid filter cut-off frequency

  Index1 = 3 is the higher slope of the low-mid filter cut-off frequency

  Index1 = 4 is the lower slope of the mid-high filter cut-off frequency

  Index1 = 5 is the higher slope of the mid-high filter cut-off frequency

  Index1 = 6 is the high-pass filter cut-off frequency

 

 

Example: Get Device 2 Crossover 3-Way Cut-Off Frequency at Instance 40 Low-Pass filter.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

GET

2

XOVR3FC

40

1

None

None

<LF>

 

Result: GET 2 XOVR3FC 40 1 <LF>