Dynamics Blocks

 

Leveler

Attribute

Commands

Index

Value Range

Bypass

LVLRBYP

SET, GET, SETD, GETD

None

0 = active

1 = bypassed

 

 

 

Comp/Limiter

Attribute

Commands

Index

Value Range

Bypass

CLIMBYP

SET, GET, SETD, GETD

None

0 = active

1 = bypassed

 

 

 

Ducker

Attribute

Commands

Index

Value Range

Input Level

DKRLVLIN

SET, GET, SETL, GETL, SETD, GETD

None

-100 ~ 12 *

Level Sense

DKRLVLSENSE

SEET, GET, SETL, GETL, SETD, GETD

None

-100 ~ 12 *

Bypass Ducker

DKRBYP

SET, GET, SETD, GETD

None

0 = active

1 = bypassed

 Sense Mute

DKRMUTESENSE

SET, GET, SETD, GETD

None

0 = unmuted

1 = muted

Input Mute

DKRMUTEIN

SET, GET, SETD, GETD

None

0 = unmuted

1 = muted

Logic In Enable

DKRENLOGIN

SET, GET, SETD, GETD

None

0 = disabled

1 = enabled

Logic Out Enable

DKRENLOGOUT

SET, GET, SETD, GETD

None

0 = disabled

1 = enabled

Logic Input Invert

DKRINVLOGIN

SET, GET, SETD, GETD

None

0 = normal

1 = inverted

Logic Output Invert

DKRINVLOGOUT

SET, GET, SETD, GETD

None

0 = normal

1 = inverted

 

* Can contain a decimal number.

 

 

Noise Gate

Attribute

Commands

Index

Value Range

Bypass

NGBYP

SET, GET, SETD, GETD

None

0 = active

1 = bypassed

 

 

Example: Set Device 3 Noise Gate Bypass at Instance 55 to active.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET

3

NGBYP

55

None

None

0

<LF>

 

Result: SET 3 NGBYP 55 0 <LF>