2-Way |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
XOVR2FC |
SET, SETL, GET, GETL, SETD, GETD |
1 |
20 ~ 20000 * |
* Can contain a decimal number.
3-Way |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
XOVR3FC |
SET, SETL, GET, GETL, SETD, GETD |
1 |
20 ~ 20000 * |
* Can contain a decimal number.
4-Way |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
XOVR4FC |
SET, SETL, GET, GETL, SETD, GETD |
1 |
20 ~ 20000 * |
* Can contain a decimal number.
Notes:
2-way crossover:
Index1 = 1 is the low-pass filter cut-off frequency
Index1 = 2 is the high-pass filter cut-off frequency
3-Way crossover:
Index1 = 1 is low-pass filter cut-off frequency
Index1 = 2 is the lower slope of the mid filter cut-off frequency
Index1 = 3 is the higher slope of the mid filter cut-off frequency
Index1 = 4 is the high-pass filter cut-off frequency
4-way crossover:
Index1 = 1 is the low-pass filter cut-off frequency
Index1 = 2 is the lower slope of the low-mid filter cut-off frequency
Index1 = 3 is the higher slope of the low-mid filter cut-off frequency
Index1 = 4 is the lower slope of the mid-high filter cut-off frequency
Index1 = 5 is the higher slope of the mid-high filter cut-off frequency
Index1 = 6 is the high-pass filter cut-off frequency
Example: Get Device 2 Crossover 3-Way Cut-Off Frequency at Instance 40 Low-Pass filter.
Command |
Dev # |
Attribute |
Inst ID |
Index 1 |
Index 2 |
Value |
Line Feed |
GET |
2 |
XOVR3FC |
40 |
1 |
None |
None |
<LF> |
Result: GET 2 XOVR3FC 40 1 <LF>