HPF |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
HPFLTFC |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
20 ~ 20000* |
Filter Bypass |
HPFLTBYP |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
LPF |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
LPFLTFC |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
20 ~ 20000* |
Filter Bypass |
LPFLTBYP |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
High Shelf |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
HSFLTFC |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
20 ~ 20000* |
Gain |
HSFLTGAIN |
SET, SETL, GET, GETL, SETD, GETD |
None |
-27 ~ 9 * |
Filter Bypass |
HSFLTBYP |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
Low Shelf |
Attribute |
Commands |
Index |
Value Range |
Cut-Off Freq. |
LSFLTFC |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
20 ~ 20000* |
Gain |
LSFLTGAIN |
SET, SETL, GET, GETL, SETD, GETD |
None |
-27 ~ 9 * |
Filter Bypass |
LSFLTBYP |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
Example: Set Device 1 High Shelf Filter Gain at Instance 100 to -10dB.
Command |
Dev # |
Attribute |
Inst ID |
Index 1 |
Index 2 |
Value |
Line Feed |
SET |
1 |
HSFLTGAIN |
100 |
None |
None |
-10 |
<LF> |
Result: SET 1 HSFLTGAIN 100 10 <LF>
All-Pass Shelf |
Attribute |
Commands |
Index |
Value Range |
Bandwidth |
APFLTBWBND |
SET, SETL, GET, GETL, SETD, GETD |
1 |
0.01 ~ 4.0 * |
Center Freq. |
APFLTFCBND |
SET, SETL, GET, GETL, SETD, GETD |
1 |
20 ~ 20000 * |
Filter Bypass |
APFLTFBYBND |
SET, GET, SETD, GETD |
1 |
0 = active 1 = bypassed |
Bypass All |
APFLTBYPALL |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
Note: Index1 represents the filter band to be controlled. All-Pass Filter bands are initially numbered from left to right, and the selected band is displayed in the upper left hand corner of the All-Pass Filter dialog screen in Nexia software. Use this number as Index1 for All-Pass Filter strings.